Square D Homeline's Unique OCPD Benefit
In this video I show you why Square D HOM circuit breakers allow for dual-conductor installation.
Electrical Wiring is NOT a hobby. Call a licensed electrician!
Classic Electric, LLC | Point Pleasant, New Jersey
License & Business Permit # 16557
(732)-770-1437
Want to be an electrician? Start here: www.myelectriccareer.com
Ron Pecina Jr. is a licensed electrician in the state of New Jersey since 2009.
This allows him to apply for electrical permits, work with live conductors, remove meters, and disconnect service from the utility company.
New Jersey observes the 2020 NEC and the Uniform Construction Code.
The majority of the work you’ll see on my channel falls under the New Jersey Rehabilitation Sub Code (Chapter 6 of the U.C.C.) www.nj.gov/dca/divisions/codes/codreg/pdf_regs/njac_5_23_6.pdf
* ALL New Jersey licensed electricians MUST complete 34-hours of continuing education units each tricentennial period.
* This includes a mandatory 9-hour code update course and (1) hour business law class.
* Any work above 10-volts requires an electrical license in New Jersey.
*
Become an NJ-IEC member here: www.nj-iec.org
Ron is an active member of the New Jersey Independent Electrical Contractors Association.
Contact: newjersey@ieci.org (732)-276-2295
Since 2023, Ron has been an apprenticeship instructor at the NJ-IEC Education and Training Center, Somerset, NJ.
IEC National: www.ieci.org
Customer Guide for Electrical Installation; JCPL: www.firstenergycorp.com/content/dam/customer/service%20requests/files/Customer-Guide-for-Electric-Service-NJ.pdf
Customer Guide for Electrical Installation; PSEG: nj.pseg.com/businessandcontractorservices/constructionandrenovationservices//-/media/pseg/global/gathercontentdocuments/7-2-1upgradesandnewinstallationsnew/info_and_requirements_electric_service.ashx
WANT TO SEE MORE? FULL 200 AMP SERVICE UPGRADE. WATCH HERE: ua-cam.com/video/gBysKC70WIk/v-deo.htmlsi=TVEM_KDom0YfSpd0
Classic Electric, LLC is a Generac standby air-cooled generator installer and authorized dealer.
Ron Pecina Jr’s set up:
Camera: Go Pro 9/ 10 w/ the Media Mod
Microphone: DJI Wireless
Editing software: Apple iMovie
Animation software: Apple Keynote
Background Music & Sound Effects by Soundstripe.com
Like, Share, and Subscribe!
Переглядів: 2 259

Відео

200 AMP Panel Upgrade w/ new Electric Vehicle Circuit for a Level 2 Electric Vehicle Charger
Переглядів 4,4 тис.19 годин тому
In this video a 100 amp panel is upgraded to 200 amps and and new Electric Vehicle Supply Equipment is installed. It's a 60 amp, 240 volt circuit and a Chargepoint EV Charger. Electrical Wiring is NOT a hobby. Call a licensed electrician! Classic Electric, LLC | Point Pleasant, New Jersey License & Business Permit # 16557 (732)-770-1437 Want to be an electrician? Start here: www.myelectriccaree...
Completely upgrading an existing 120/ 240V electrical service to 200 AMPS
Переглядів 13 тис.21 годину тому
In this video I completely upgrade this existing electrical service from 100A - 200A. This includes a new 200A meter, 200A service-rated NEMA3 main disconnect switch, and an updated grounding electrode system. Enjoy this video and thanks for subscribing to the channel! Electrical Wiring is NOT a hobby. Call a licensed electrician! Classic Electric, LLC | Point Pleasant, New Jersey License & Bus...
Rewiring An Old Detached Garage with 1/2" EMT Conduit | Westfield, NJ
Переглядів 8 тис.21 день тому
In this video I disconnect old knob & tube wiring and install new (2) new switches, (4) new receptacles, and (2) new porcelain lamp holders in EMT conduit in this home originally built in 1909. Everything in this garage is GFCI-protected. Electrical Wiring is NOT a hobby. Call a licensed electrician! Classic Electric, LLC | Point Pleasant, New Jersey License & Business Permit # 16557 (732)-770-...
Upgrading an electrical service to 200A for Tesla EV Charger | Overhead Electrical Service | 4K
Переглядів 10 тис.Місяць тому
In this video you’ll see how I upgraded an overhead electrical service complete with a new 200A meter, service-rated disconnect, and a 40/ 80 circuit electrical panel. The grounding electrode system was completely updated too. I hope you enjoy this video and will consider subscribing the channel. The white button connectors used in this video are by Arlington, model # NM94X. 👍 Electrical Wiring...
Upgrading a sub-panel for new A/C equipment | 30-circuit MLO panel installation
Переглядів 5 тис.2 місяці тому
In this video I'll show you how I upgraded an existing sub-panel from 8-circuit to 30-circuit and why the A/C condensing unit should be derived from the main breaker panel. Thanks for watching this video. Please leave questions you may have in the comments section below. Electrical Wiring is NOT a hobby. Call a licensed electrician! Classic Electric, LLC | Point Pleasant, New Jersey License & B...
Upgrading an electrical service from 100A to 200A | Clark, New Jersey
Переглядів 17 тис.2 місяці тому
In this video you'll see how I upgraded an electrical service, complete with the newly required EXTERIOR SERVICE DISCONNECT as required by NEC Article 230.85 and whole house surge protection as required by NEC Article 230.67. Sit back, relax, and enjoy the videos. I encourage your comments and/ or questions in the comment section below. Electrical Wiring is NOT a hobby. Call a licensed electric...
400 AMP Underground Meter Replacement JCPL | Mantoloking, N.J.
Переглядів 6 тис.3 місяці тому
In this video an underground electrical service utility meter enclosure is replaced. JCPL had come out to disconnect the power early in the morning and returned after the work was inspected to re-energize the service. Electrical Wiring is NOT a hobby. Call a licensed electrician! Classic Electric, LLC | Point Pleasant, New Jersey License & Business # 16557 (732)-770-1437 Want to be an electrici...
YouTube Subscriber in Toms River Gets a 200A Service Upgrade | Underground Electrical Service in 4k
Переглядів 44 тис.3 місяці тому
In this video you’ll see how I upgraded an underground electrical service complete with a new 200A meter, service-rated disconnect, and a 40/ 80 circuit electrical panel. The grounding electrode system was completely updated too. I hope you enjoy this video and will consider subscribing the channel. Electrical Wiring is NOT a hobby. Call a licensed electrician! Classic Electric, LLC | Point Ple...
Saratoga Tool Vest by Atlast 46
Переглядів 3 тис.3 місяці тому
Saratoga Tool Vest by Atlast 46
EVERY HOME NEEDS AN ELECTRICAL SERVICE | Point Pleasant Beach House #5
Переглядів 9 тис.4 місяці тому
EVERY HOME NEEDS AN ELECTRICAL SERVICE | Point Pleasant Beach House #5
Point Pleasant Beach House #4 | Kitchen Wiring and Branch Circuit Requirements
Переглядів 4,2 тис.4 місяці тому
Point Pleasant Beach House #4 | Kitchen Wiring and Branch Circuit Requirements
Laying out boxes and running wires at the beach house | PPBH Part III
Переглядів 3,7 тис.4 місяці тому
Laying out boxes and running wires at the beach house | PPBH Part III
Preserving Legacy, Powering the Future: Connecting Existing Wiring to New Branch Circuits
Переглядів 4,8 тис.4 місяці тому
Preserving Legacy, Powering the Future: Connecting Existing Wiring to New Branch Circuits
COMPLETE INSTALLATION OF A NEW BRANCH CIRCUIT FOR AN ELECTRIC VEHICLE CHARGER BY AUTEL
Переглядів 10 тис.5 місяців тому
COMPLETE INSTALLATION OF A NEW BRANCH CIRCUIT FOR AN ELECTRIC VEHICLE CHARGER BY AUTEL
200 AMP ELECTRIC SERVICE RISER REPLACEMENT #electrical #electrician
Переглядів 34 тис.6 місяців тому
200 AMP ELECTRIC SERVICE RISER REPLACEMENT #electrical #electrician
Broken Lamp Repair
Переглядів 9176 місяців тому
Broken Lamp Repair
Generac: Smart Management Module Installation, 100 AMP
Переглядів 8 тис.6 місяців тому
Generac: Smart Management Module Installation, 100 AMP
JuiceBox 40 AMP Smart Electric Vehicle - 40 amp Level 2 EVSE, w/ 25-Foot Cable installation
Переглядів 5 тис.6 місяців тому
JuiceBox 40 AMP Smart Electric Vehicle - 40 amp Level 2 EVSE, w/ 25-Foot Cable installation
Stay Warm: Supplement Your Gas Furnace with an Electric Baseboard Heater
Переглядів 4,5 тис.7 місяців тому
Stay Warm: Supplement Your Gas Furnace with an Electric Baseboard Heater
Generac 7209 200A Automatic-Transfer Switch Part 2 (of 2) | Osterville, Cape Cod
Переглядів 11 тис.7 місяців тому
Generac 7209 200A Automatic-Transfer Switch Part 2 (of 2) | Osterville, Cape Cod
Generac 7209 24/ 21 Air-Cooled Standby Generator Part 1 (of 2) | Osterville, Cape Cod
Переглядів 10 тис.7 місяців тому
Generac 7209 24/ 21 Air-Cooled Standby Generator Part 1 (of 2) | Osterville, Cape Cod
Garage Wiring Code Violations
Переглядів 11 тис.8 місяців тому
Garage Wiring Code Violations
Point Pleasant Beach House - Part One
Переглядів 3,2 тис.8 місяців тому
Point Pleasant Beach House - Part One
Installing a Chargepoint Electric Vehicle Charger for Seamless Charging at Home #evse #chargepoint
Переглядів 18 тис.8 місяців тому
Installing a Chargepoint Electric Vehicle Charger for Seamless Charging at Home #evse #chargepoint
Powerage II: An Electrical Contractor's Journey of Updating His Own Electrical Service Part II
Переглядів 15 тис.9 місяців тому
Powerage II: An Electrical Contractor's Journey of Updating His Own Electrical Service Part II
An Electrical Contractor's Journey | Portable Generator Wiring Part One
Переглядів 8 тис.9 місяців тому
An Electrical Contractor's Journey | Portable Generator Wiring Part One
From Breakdown to Breakthrough: Fixing a Broken Meter Lug and Upgrading to a 200 Amp Service
Переглядів 13 тис.9 місяців тому
From Breakdown to Breakthrough: Fixing a Broken Meter Lug and Upgrading to a 200 Amp Service
United States Kilowatt Hours in 2022 was 4.5 Trillion
Переглядів 91310 місяців тому
United States Kilowatt Hours in 2022 was 4.5 Trillion
Exterior Recessed Light Upgrade - Retrofit old-school Lightolier to new LED's by RAB
Переглядів 5 тис.10 місяців тому
Exterior Recessed Light Upgrade - Retrofit old-school Lightolier to new LED's by RAB

КОМЕНТАРІ

  • @mbforwood6926
    @mbforwood6926 2 години тому

    Great video - thank you! Looking at picking this up, still happy with yours? How’s the wear and tear on the bag after 2 years. Looking at maybe the blackout version of this bag. Not sure, so many warn of a black color tool bag - would like to hear your thoughts or that of others.

    • @electricalron
      @electricalron Годину тому

      Yes I would highly recommend this TP XXL. It’s my every day carry for service. The tape measure clip on the front got snagged one day but it was totally my fault and it’s only a small test from the fabric. Everything else on it is still mint.

    • @mbforwood6926
      @mbforwood6926 Годину тому

      @@electricalron Thank you for your response! Since your in the trade, any thoughts or anyone you know have the blackout version of the top-xxl and complaints on cleanliness or vice versa with the color you have?

  • @Rowganlife
    @Rowganlife 3 години тому

    thanks so much for the information!

  • @pstew124
    @pstew124 6 годин тому

    Seal of approval for top electrician who also listens to Motorhead's 'Ace of Spades' .

  • @Sparky-joystick.1308
    @Sparky-joystick.1308 8 годин тому

    The panel looks really clean. I from Wisconsin I graduate electrical school .May now apprenticeship in residential electrician 3 years journeyman license how long to be a master electrician your opinion

  • @littletang92
    @littletang92 17 годин тому

    Is there much difference between a homeline and a Eaton BR panel? My eletrican said was having trouble finding homeline panels and was wondering if I would be ok with an Eaton panel.

  • @vincentdangelo8024
    @vincentdangelo8024 День тому

    The water meter needed an electrical connection? Is that unusual?

  • @dalejones2108
    @dalejones2108 День тому

    Quack quack says the duck seal

  • @dalejones2108
    @dalejones2108 День тому

    Do you really want a fridge on GFCI there notorious for tripping

  • @BearStar1
    @BearStar1 День тому

    In Tx , that 4/0 SE Romex Cable for 200 Amp Services is not allowed for outside install ! Contractors will buy the cable and then strip off and remove the Outer Jacket Sheathing and the inner snake skin from the 4/0 AL Conductors and run the individual conductors up in the 2 '' Rigid Galvanized Steel Conduit Mast and out the attached Weatherhead for the Service Loop Connections.

  • @liketohike69
    @liketohike69 День тому

    Hi Ron, I have a question about backer board. I'm in PA and upgrading a service on property I just bought. It's mostly an open lot with bathrooms, a pavilion and some plugs. I removed the rusted rotted panel and plan on putting 2 -4x4 pressure treated posts in the ground with 5/4" decking horizontal to the 4x4's and putting a combo outdoor meter/breaker box with 2 new ground rods, (there were none before, just a wire into the ground stapled to the bottom of a rotted section of telephone pole). So the question, is the 5/4" pressure treated okay? should it be 2x4's? Painted plywood? Funny story for next time about the power being off "NOT" when I started working taking the stuff apart. Thanks,

  • @123davann
    @123davann День тому

    Southwire EZLB200 Connector; 2"; Gray. Hi Ron love the videos did you ever use this LB Makes it easier when using 4/0 SE cable ? thanks Dave Murphy

  • @doc13067
    @doc13067 День тому

    Great video! One of the o key channels that shows the whole process. I’m over in Philly and the heat has been unreal. We’ve been in attics doing recessed lighting. Does NJ allow you to put the main at the bottom so you don’t have to run 4/0 from the bottom to the top? Or is that prohibited by that uniform code. We only have the 2017 NEC where I work

  • @matthewboatman705
    @matthewboatman705 День тому

    Building code also states that floor joists cannot have holes drilled less than 2 inches from the bottom of the edge. So always put your wires higher than 1 1/2 inches from the edge.

  • @TedTedness
    @TedTedness День тому

    The grid can't take the EV power need and "they " won't improve it much. We will need 50 nuclear power plants to feed the future they seem to wish for. Remember, they are banning all natural gas appliances. Their plan is to deny you having a car in the future. If you are 20 years old now, I bet you will be denied a 2 car family or even a 1 car family by the time your 60.

  • @PvMTerry
    @PvMTerry День тому

    What’s the reasoning for this customer to upgrade from 100 to 200 service ?

    • @electricalron
      @electricalron День тому

      Not much has been updated at the house since it was built in the 1950's. A new kitchen, updated bathroom, maybe a master bedroom addition, etc. Clearly they'll require multiple new 15 and 20 amp circuits. Demand for electricity is forever growing and has been since it's inception.

    • @PvMTerry
      @PvMTerry День тому

      @@electricalron can you upgrade to 200 amp if you still have some knob and tube ?

  • @wirenut9062
    @wirenut9062 2 дні тому

    When the 2023 code adoption hits you will have to install a disco for a panel change with the new note In 230.85. In north jersey some inspectors are requiring it already

    • @electricalron
      @electricalron 2 дні тому

      The North Jersey inspectors? Rules apply to all of NJ, not just Bergen, Essex and Passaic counties. The Uniform Construction Code which supersedes the NEC does not require an exterior disconnect for panel changes. It's only on "full service upgrades" and spells it out clearly. There's a link to the UCC in the description of every video I post.

  • @Pembroke.
    @Pembroke. 2 дні тому

    Happy 4th of July, Ron 🍺🍺as I get ready to celebrate Canada Day FP, my brother has BE116-20 with AL wires. The 30 amp dryer breaker kept tripping. He wants to replace the breaker, not the unit. We've discussed it, but it's hard to convince him.

  • @sriharigopal3745
    @sriharigopal3745 2 дні тому

    Very helpful video, thanks for sharing.

  • @donmclean1220
    @donmclean1220 2 дні тому

    I bought a house in 2019 with a home inspection that stated “ one half of receptacle in living room not working “. I went to a hallway switch, flipped it up, and amazingly the receptacle now worked!

  • @user-gu9lf5go2t
    @user-gu9lf5go2t 2 дні тому

    I'm Abigail kiss fan I never got to go to a concert be cause of my parents are Babtest but I have a lot of there lps

  • @reallunacy
    @reallunacy 2 дні тому

    My only complaint would be that I would have liked to see the GFCI mounted at an ADA accessible height.

  • @jfowler702910
    @jfowler702910 2 дні тому

    Why did you install a main breaker panel along with a main breaker disconnect? Is the exterior service entrance disconnect required by code now? Years ago if I was putting in a main breaker panel I would come directly out of the meter housing and right into the main breaker panel with my service kick. There wouldn't be any exterior disconnect unless the main panel was located more than 3 ft inside the dwelling. If so then we would use a main breaker exterior disconnect with an interior main lug panel.

  • @reallunacy
    @reallunacy 2 дні тому

    That aluminum siding is "fun", I have it on my home.

  • @Pembroke.
    @Pembroke. 3 дні тому

    Excellent Job Ron!

  • @ShawnAtTheGame
    @ShawnAtTheGame 3 дні тому

    Thank you for this! Novice here…If the wiring is 12/2 grounded at all junctions, why is gfci necessary?

  • @jro21
    @jro21 3 дні тому

    How much does this usually cost to do changing service from 100 to 200?

  • @gtbr8134
    @gtbr8134 4 дні тому

    Is that a medium roof?

  • @williamradwanski1998
    @williamradwanski1998 4 дні тому

    Retired service tech from Schneider electric now living in AZ. I recently had problems with my outdoor 200 amp service. Had to replace a 30 amp circuit breaker for my outdoor AC unit. I took a temperature reading of the outside of the box when the sun was going down and would hit the box. The temperature was 150 degrees F. I found the high temperature out here causes nuisance c!b tripping and c/b failures. Way different than PA.

    • @electricalron
      @electricalron 4 дні тому

      Crazy having that equipment outside with the sin blazing down on it.

  • @ericthat
    @ericthat 4 дні тому

    Florida Fans congratulations. Overall good post. Thanks

  • @BigD63
    @BigD63 4 дні тому

    Ron, once again great video and content. Best regards from Chicago ...

  • @fordoha
    @fordoha 4 дні тому

    How much does a service like this cost?

  • @fordoha
    @fordoha 4 дні тому

    Hey Ron, how much does a job like this cost?

    • @fordoha
      @fordoha 4 дні тому

      How much Ron?

  • @user-gu9lf5go2t
    @user-gu9lf5go2t 5 днів тому

    In NC we use bare copper wire for ground rods and tie in the meter base

    • @electricalron
      @electricalron 4 дні тому

      That's probably a utility requirement.

  • @Makitafan
    @Makitafan 5 днів тому

    24:28 if it breaks in half they own both halves! 🤣🤣 JK

  • @ramonmartinez3889
    @ramonmartinez3889 5 днів тому

    I was wondering about the cost to upgrade a 100 to 200 amps panel in 2024. The last time I had this done was almost 10 years ago.

  • @rodolfovesga979
    @rodolfovesga979 5 днів тому

    Cool trick with 2 by 4

  • @johnnydo6410
    @johnnydo6410 5 днів тому

    How much would cost me labor and parts boss? I need upgrade my old house build 1978. I am in Seattle wa

  • @mikegrimaldi5844
    @mikegrimaldi5844 5 днів тому

    Good video. I would like to learn how to properly crimp those spade connectors as I have issues using screw connections with THHN stranded wire.

  • @user-hl7bi1cv6l
    @user-hl7bi1cv6l 5 днів тому

    When you cut the alive service wire, which one you cut first?

  • @OSAS726
    @OSAS726 5 днів тому

    Good morning Ron! My question is what were you talking about when you were saying to make sure that the transformer had a lower fault current protection than the disconnect breaker? Maybe I’m misunderstanding? I’ve never heard of that. I’m just curious as to what that is? Thanks in advance for your response. BTW, great content. I love your channel.

  • @MrJujubean
    @MrJujubean 5 днів тому

    You do great work

  • @elangomattab
    @elangomattab 5 днів тому

    Thanks for recommending minimum of 40 full size breakers for new panel installs. My panel is an old Square D QO with 200 amps but only has 30 breaker spaces with 6 of those allowing twin breakers. I don't have any double breakers yet but my panel is full due mostly to my electric heating system. I don't even have space for an EV charger right now even if i could afford an EV.

  • @zekenzy6486
    @zekenzy6486 6 днів тому

    Great video. Thank you for sharing

  • @donmclean1220
    @donmclean1220 6 днів тому

    Is there any minimum distance from the electric meter to the gas meter?

    • @electricalron
      @electricalron 6 днів тому

      Not in an existing installation.

    • @donmclean1220
      @donmclean1220 2 дні тому

      Thanks, I remember reading the PGE “green book” having all sorts of distance requirements in it, but of course, they are for new construction. I get the difference.

  • @zekenzy6486
    @zekenzy6486 6 днів тому

    Great video. Thank you for sharing.

  • @mattmiller8251
    @mattmiller8251 6 днів тому

    Love your videos as always! I like when my mains coming into the panel come in beside the lugs so i don't take up so much room in the side of the panel.

  • @chrisw6435
    @chrisw6435 6 днів тому

    Sorry, but I do not get it… is this double tap situation when you are combining 2 circuits that respect the circuit load percentage? In certain regions double tapping is simply not allowed no matter the situation. Please if you can explain in more detail. Thanks

  • @mikes5819
    @mikes5819 6 днів тому

    Soooooo loud I just bought one now in thinking no

  • @jeffbecraft7174
    @jeffbecraft7174 6 днів тому

    We just add another breaker..and charge for it. Just to speed thing up

  • @user-gu9lf5go2t
    @user-gu9lf5go2t 6 днів тому

    I was and electriction for maney years retired now but still have to do some side work